{"product_id":"ati-icp-lab-analysis-ultimate-ms","title":"ATI ICP Lab Analysis Ultimate MS","description":"\u003cp\u003eThe ATI ICP Lab Analysis Ultimate MS is ATI's most comprehensive mail-in analysis. It includes everything in the Pro analysis plus ICP-MS measurement of trace elements and pollutants down to the ultra-trace range, with many parameters double-checked by both ICP-OES and ICP-MS. Return shipping is included.\u003c\/p\u003e\n\u003ch3 style=\"margin:16px 0 4px;font-size:1.05em;font-weight:600;line-height:1.25;border-left:4px solid #006064;padding-left:8px;\"\u003eWhat it measures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSalinity\u003c\/li\u003e\n\u003cli\u003eMajor elements: sodium, calcium, chloride, magnesium, sulfur, potassium, bromine, strontium, boron\u003c\/li\u003e\n\u003cli\u003eOES trace elements: arsenic, barium, beryllium, chromium, cobalt, iron, iodine, copper, lithium, manganese, molybdenum, nickel, selenium, silver, silicon, vanadium, zinc, tin\u003c\/li\u003e\n\u003cli\u003eOES pollutants: aluminum, antimony, bismuth, cadmium, lanthanum, thallium, titanium, tungsten, mercury\u003c\/li\u003e\n\u003cli\u003eMS trace elements: arsenic, chromium, cobalt, copper, manganese, nickel, rubidium, selenium, vanadium, zinc, tin\u003c\/li\u003e\n\u003cli\u003eMS pollutants: lead, neodymium, niobium, zirconium, indium, germanium, gallium, mercury, tellurium\u003c\/li\u003e\n\u003cli\u003ePhosphate \/ phosphorus, nitrate and fluorine, alkalinity (KH)\u003c\/li\u003e\n\u003cli\u003eAnalysis of your reverse osmosis water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:16px 0 4px;font-size:1.05em;font-weight:600;line-height:1.25;border-left:4px solid #006064;padding-left:8px;\"\u003eWhy Ultimate MS\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble validation:\u003c\/strong\u003e Many parameters are measured by both ICP-OES and ICP-MS and checked against each other.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUltra-trace detection:\u003c\/strong\u003e Detection down to 0.001 µg\/L for some elements; ATI states ICP-MS detection limits are up to 10,000 times lower than other ICP systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarlier pollutant warning:\u003c\/strong\u003e Pollutants are detected earlier and more precisely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtra elements:\u003c\/strong\u003e Measures elements ICP-OES can't, such as rubidium, neodymium and zirconium.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:16px 0 4px;font-size:1.05em;font-weight:600;line-height:1.25;border-left:4px solid #006064;padding-left:8px;\"\u003eHow it works\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eRegister at lab.atiaquaristik.com, create an aquarium profile and scan the QR code to activate the analysis\u003c\/li\u003e\n\u003cli\u003eFill the sample tube with aquarium water (and RO water, where the analysis includes it)\u003c\/li\u003e\n\u003cli\u003eApply the barcodes and send the sample to the return address provided\u003c\/li\u003e\n\u003cli\u003eStatus updates and your results arrive by email\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"margin:16px 0 4px;font-size:1.05em;font-weight:600;line-height:1.25;border-left:4px solid #006064;padding-left:8px;\"\u003eWhich ATI analysis do I need?\u003c\/h3\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:0.95em;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding:6px 10px;border:1px solid #B2EBF2;background:#E0F7FA;text-align:left;\"\u003e\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px;border:1px solid #B2EBF2;background:#E0F7FA;text-align:left;\"\u003eStandard\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px;border:1px solid #B2EBF2;background:#E0F7FA;text-align:left;\"\u003ePro\u003c\/th\u003e\n\u003cth style=\"padding:6px 10px;border:1px solid #B2EBF2;background:#E0F7FA;text-align:left;\"\u003eUltimate MS\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eICP-OES\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eICP-OES, ion chromatography, titration\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eICP-MS, ICP-OES, ion chromatography, titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eSalinity, major elements, phosphate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eOES trace elements and pollutants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes (medium detection limits)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes (medium detection limits)\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes, double-validated by ICP-OES and ICP-MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eNitrate and fluorine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eAlkalinity (KH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eRO water analysis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eMS trace elements and MS pollutants\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eNo\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eYes (ultra-trace range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eATI's summary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eSolid basic analysis for the price-conscious user\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eComprehensive analysis with all important parameters\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eMost comprehensive, including all pollutants and ultra-trace elements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:16px 0 4px;font-size:1.05em;font-weight:600;line-height:1.25;border-left:4px solid #006064;padding-left:8px;\"\u003eAbout ATI lab testing\u003c\/h3\u003e\u003cp\u003eATI's lab in Germany, headed by Dr. Ben Funk, uses professional ICP-OES, ICP-MS, ion chromatography and titration equipment, choosing the most suitable method for each parameter. ATI positions lab analysis as far more accurate and consistent than standard hobby test kits, and it covers many elements a hobby kit can't measure. Correct what the report shows with the matching \u003ca href=\"https:\/\/squeakysaquatics.com\/collections\/reef-supplements\"\u003eATI ICP Element\u003c\/a\u003e supplements.\u003c\/p\u003e\n\u003ch3 style=\"margin:16px 0 4px;font-size:1.05em;font-weight:600;line-height:1.25;border-left:4px solid #006064;padding-left:8px;\"\u003eSpecifications\u003c\/h3\u003e\u003ctable style=\"border-collapse:collapse;width:100%;font-size:0.95em;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eATI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eICP-MS, ICP-OES, ion chromatography, titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003ePack sizes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e1 or 3 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eIncludes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eTank water and RO water analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eReturn shipping\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eLab\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eATI lab, Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eWater type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003eSaltwater and reef\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e\u003cstrong\u003eUPCs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:6px 10px;border:1px solid #B2EBF2;\"\u003e4260216216909, 4260216216916\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3 style=\"margin:16px 0 4px;font-size:1.05em;font-weight:600;line-height:1.25;border-left:4px solid #006064;padding-left:8px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHow is it different from Pro?\u003c\/strong\u003e It adds ICP-MS measurement of trace elements and pollutants at ultra-low detection limits, with double validation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs return shipping included?\u003c\/strong\u003e Yes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it include RO water?\u003c\/strong\u003e Yes, the RO water analysis is included.\u003c\/p\u003e","brand":"ATI","offers":[{"title":"1 Test","offer_id":50512671736027,"sku":"3000014US","price":69.95,"currency_code":"USD","in_stock":false},{"title":"3 Tests","offer_id":50512671768795,"sku":"3000015US","price":185.25,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/5209\/3403\/files\/ATI_ICP_Analysen_1er_Ultimate_Shop_USA_3000x3000px.jpg?v=1790233194","url":"https:\/\/squeakysaquatics.com\/products\/ati-icp-lab-analysis-ultimate-ms","provider":"Squeaky's Aquatics","version":"1.0","type":"link"}