The Milwaukee MA887 reads seawater salinity digitally, so there is no blue line to squint at and no eyepiece to hold up to a lamp. Put two or three drops on the prism, press READ, and you have a number in about a second and a half. It switches between PSU, ppt and specific gravity, and it compensates for temperature on its own. Browse the rest of our water testing gear and saltwater supplies.
This is the MA887-BOX, the kit version: the meter ships in its MA800 hard case with the calibration fluids and battery, which is the configuration you want if it is going to live in a cabinet with wet hands around it.
The display resolves specific gravity to 0.001, but Milwaukee rates the accuracy at ±0.002 S.G. (±2 ppt). Those are not the same thing. The last digit will move around more than it is strictly meaningful, so treat it as a repeatable, easy-to-read instrument rather than a laboratory reference. For reef work that is fine: what matters most is catching drift and keeping salinity stable, and a meter two people can read the same way does that better than an optical refractometer nobody wants to use. If you want to confirm it against a known value, check it with a 35 ppt calibration standard.
| Brand | Milwaukee Instruments |
| Model | MA887-BOX (MA887 meter plus MA800 case) |
| Range | 0 to 50 PSU, 0 to 150 ppt, 1.000 to 1.114 S.G. (20/20), 0 to 80°C (32 to 176°F) |
| Resolution | 1 PSU, 1 ppt, 0.001 S.G., 0.1° |
| Accuracy | ±2 PSU, ±2 ppt, ±0.002 S.G., ±0.3°C |
| Temperature compensation | Automatic, 10 to 40°C (50 to 104°F) |
| Calibration | One point, distilled or deionized water |
| Sample size | 100 µL minimum, about 2 to 3 drops |
| Measurement time | About 1.5 seconds |
| Light source | Yellow LED, flint glass prism, stainless steel sample ring |
| Battery | One 9V, about 5,000 readings, auto off after 3 minutes |
| Protection rating | IP65 |
| Meter size | 7.6 x 4 x 2.64 in, 0.93 lb |
| Water type | Seawater and brackish. Not a freshwater hardness test |
Does it come with the case?
Yes. This is the MA887-BOX, so the meter, the MA800 hard case, the 9V battery, distilled water for calibration and a 1.025 standard are all included. The bare MA887 sold elsewhere has no case and no battery.
What do I calibrate it with?
Distilled or deionized water, nothing else. One point, press ZERO. If you run an RO/DI unit you already have what you need.
Can I use it on a freshwater tank?
No. It is a seawater instrument and starts at 0 ppt; it will not tell you anything useful about freshwater hardness. Use a GH test for that.
Why does my reading drift a little between tries?
Almost always a dirty or wet prism. Dry the well between the calibration drop and the sample, and rinse the salt off after every use. If it still wanders, recalibrate.
Is it better than a handheld salinity tester?
Different tool. A refractometer needs only a couple of drops and no probe maintenance; a probe-based tester can sit in the water and read continuously. If you test by hand at the sump once a week, the refractometer is the simpler device to own.
Sold out right now
Add $29.01 more to your cart for free US shipping
Earn Squeaky's Splash Rewards points on every purchase, in store and online: 5% back, rising to 10% as you climb. Learn more
Kits
The things that go together, in one tap. Untick anything you already have.
Start the good bacteria and check when the tank is ready for fish, fresh or salt.
Kit total
Still thinking about these?